NY Type For A.S. / ACSR Stranded Wires Tension Clamp Anchor
Use And Specification
NY type tensioning clamp for aluminium clad steel stranded wire is made of aluminium forging, which is light in weight and easy to carry and install, greatly reducing the manpower cost and assembly time. With excellent corrosion resistance, it can better resist the environmental corrosion such as moisture, acid and alkali in power transmission and distribution lines, and prolong the life of the clamps. Combined with the force of aluminium-clad steel strand, it provides good support and fixation, avoiding problems such as wire vibration, swinging and falling off, ensuring the safe and stable operation of power transmission and distribution lines.
Model |
Conductor |
Main dimensions (mm) |
Grip |
Weight |
|||||||
L |
L1 |
L2 |
L3 |
D |
D1 |
D2 |
R |
||||
NY-35BG |
JLB20A-35 |
325 |
230 |
55 |
200 |
32 |
18 |
16 |
10 |
35.3 |
1.92 |
NY-50BG |
JLB20A-50 |
345 |
250 |
55 |
200 |
32 |
18 |
16 |
10 |
50.8 |
1.96 |
NY-65BG |
JLB2OA-65 |
390 |
285 |
65 |
210 |
36 |
22 |
18 |
11 |
65.5 |
2.71 |
NY-70BG |
JLB20A-70 |
390 |
285 |
65 |
210 |
36 |
22 |
18 |
11 |
69.3 |
2.76 |
NY-80BG |
JLB20A-80 |
435 |
325 |
65 |
210 |
36 |
24 |
18 |
11 |
76.0 |
3.15 |
NY-95BG |
JLB20A-95 |
450 |
340 |
65 |
250 |
40 |
26 |
18 |
11 |
85.9 |
3.75 |
NY-100BG.1 |
JLB20A-100 |
465 |
340 |
78 |
250 |
40 |
28 |
20 |
13 |
103.5 |
4.34 |
NY-100BG.2 |
JLB30A-100 |
435 |
325 |
65 |
210 |
36 |
24 |
18 |
11 |
68.0 |
3.25 |
NY-120BG.1 |
JLB20A-120 |
465 |
340 |
78 |
250 |
42 |
30 |
22 |
13 |
124.3 |
5.00 |
NY-120BG.2 |
JLB30A-120 |
450 |
340 |
65 |
250 |
40 |
26 |
18 |
11 |
81.6 |
3.75 |
NY-150BG.1 |
JLB2OA-150 |
535 |
390 |
85 |
260 |
45 |
32 |
24 |
15 |
151.8 |
6.62 |
NY-150BG.2 |
JLB30A-150 |
465 |
340 |
78 |
250 |
40 |
28 |
20 |
13 |
99.7 |
4.34 |
NY-185BG.1 |
JLB20A-185 |
575 |
435 |
85 |
260 |
48 |
34 |
24 |
15 |
117.6 |
7.92 |
NY-185BG.2 |
JLB30A-185 |
465 |
340 |
78 |
250 |
42 |
30 |
22 |
13 |
123.1 |
5.10 |
Stable Design |
Suitable |
Main dimensions (mm) |
Grip |
Weight(kg) |
|||||
L |
L2 |
D |
D1 |
D2 |
R |
||||
NY-80BG-20 |
JLR20A-80 |
435 |
70 |
36 |
24 |
18 |
12 |
85.0 |
2.5 |
NY-80BG-35 |
JLB35-80 |
435 |
65 |
36 |
24 |
18 |
12 |
53.4 |
2.5 |
NY-80BG-40 |
JLB40-80 |
435 |
65 |
36 |
24 |
18 |
12 |
46.6 |
2.5 |
NY-100BG-20 |
JLB20A-100 |
455 |
80 |
38 |
26 |
20 |
12 |
116.0 |
3.7 |
NY-100BG-35 |
JLB35-100 |
435 |
70 |
38 |
26 |
20 |
12 |
68.1 |
3.2 |
NY-100BG-40 |
JLB40-100 |
435 |
70 |
38 |
26 |
20 |
12 |
59.6 |
2.9 |
NY-120BG-20 |
JLB20A-120 |
490 |
80 |
42 |
30 |
22 |
13 |
139.0 |
3.8 |
NY-120BG-35 |
JLB35-120 |
450 |
70 |
36 |
24 |
18 |
12 |
81.9 |
2.5 |
NY-120BG-40 |
JLB40-120 |
450 |
70 |
36 |
24 |
18 |
12 |
71.5 |
2.7 |
NY-150BG-20 |
JLB20A-150 |
460 |
80 |
45 |
32 |
26 |
16 |
170.0 |
7.3 |
NY-150BG-35 |
JLB35-150 |
445 |
80 |
38 |
26 |
18 |
12 |
100.0 |
3.2 |
NY-150BG-40 |
JLB40-150 |
445 |
70 |
38 |
26 |
18 |
12 |
87.4 |
3.2 |
Model |
Suitable Conductor |
Main dimensions (mm) |
Grip |
Weight |
|||||||
L |
L1 |
L2 |
L3 |
D |
D1 |
D2 |
R |
||||
NY-35BG |
JLB20A-35 |
350 |
230 |
55 |
200 |
32 |
18 |
16 |
10 |
35.3 |
1.92 |
NY-50BG |
JLB20A-50 |
370 |
250 |
55 |
200 |
32 |
18 |
16 |
10 |
50.8 |
1.96 |
NY-65BG |
JLB20A-65 |
415 |
285 |
65 |
210 |
36 |
22 |
18 |
11 |
65.5 |
2.71 |
NY-70BG |
JLB20A-70 |
415 |
285 |
65 |
210 |
36 |
22 |
18 |
11 |
69.3 |
2.76 |
NY-80BG |
JLB20A-80 |
460 |
325 |
65 |
210 |
36 |
24 |
18 |
12 |
76.0 |
3.15 |
NY-95BG |
JLB20A-95 |
475 |
340 |
65 |
250 |
40 |
26 |
18 |
13 |
85.9 |
3.75 |
NY-100BG.1 |
JLB20A-100 |
500 |
340 |
78 |
250 |
40 |
28 |
20 |
14 |
103.5 |
4.34 |
NY-100BG.2 |
JLB30A-100 |
460 |
325 |
65 |
210 |
36 |
24 |
18 |
12 |
68.0 |
3.25 |
NY-120BG.1 |
JLB20A-120 |
500 |
340 |
78 |
250 |
42 |
30 |
22 |
15 |
124.3 |
5.00 |
NY-120BG.2 |
JLB30A-120 |
475 |
340 |
65 |
250 |
40 |
26 |
18 |
13 |
81.6 |
3.75 |
NY-150BG.1 |
JLB20A-150 |
580 |
390 |
85 |
260 |
45 |
32 |
24 |
16 |
151.8 |
6.62 |
NY-150BG.2 |
JLB30A-150 |
500 |
340 |
78 |
250 |
40 |
28 |
20 |
14 |
99.7 |
4.34 |
NY-185BG.1 |
JLB20A-185 |
620 |
435 |
85 |
260 |
48 |
34 |
24 |
17 |
117.6 |
7.92 |
NY-185BG.2 |
JLB30A-185 |
500 |
340 |
78 |
250 |
42 |
30 |
22 |
15 |
123.1 |
5.10 |
Model |
Suitable Conductor |
Main dimensions(mm) |
Grip(kN) |
Weight(kg) |
||||||
L |
L2 |
L3 |
D |
D1 |
D2 |
R |
||||
NY-70/40BG |
ACSR/AS-70/40 |
480 |
50 |
220 |
34 |
16 |
16 |
9.0 |
57.8 |
0.4 |
NY-80/47BG |
ACSR/AS-80/47 |
475 |
70 |
230 |
36 |
18 |
16 |
10.0 |
64.6 |
3.1 |
NY-95/55BG |
ACSR/AS-95/55 |
486 |
65 |
230 |
36 |
20 |
18 |
11.0 |
74.0 |
2.9 |
NY-185/30BG |
ACSR/AS-185/30 |
540 |
55 |
220 |
36 |
16 |
16 |
9.0 |
62.9 |
2.9 |
NY-240/40BG |
ACSR/AS-240/40 |
595 |
65 |
240 |
38 |
18 |
18 |
12.0 |
81.6 |
3.3 |
NY-300/25BG |
ACSR/AS-300/25 |
560 |
55 |
265 |
42 |
18 |
18 |
11.5 |
74.4 |
3.6 |
NY-300/40BG |
ACSR/AS-300/40 |
615 |
70 |
265 |
42 |
18 |
18 |
13.0 |
90.0 |
3.8 |
NY-300/50BG |
ACSR/AS-300/50 |
620 |
70 |
265 |
42 |
18 |
18 |
13.0 |
101.0 |
4.1 |
NY-300/70BG |
ACSR/AS-300/70 |
625 |
70 |
265 |
42 |
22 |
22 |
13.0 |
117.8 |
4.4 |
NY-400/35BG |
ACSR/AS-400/35 |
635 |
65 |
280 |
48 |
18 |
18 |
13.0 |
99.0 |
5.2 |
NY-400/50BG |
ACSR/AS-400/50 |
645 |
65 |
280 |
48 |
20 |
20 |
13.0 |
|
5.2 |
Summary
NY type tensioning clamp for aluminium clad steel stranded wires is a kind of tensioning clamp specially used for clamping power lines, this kind of tensioning clamp has the advantages of compact structure, easy installation and large clamping force, which can effectively guarantee the stable operation of power lines. In the construction, we should choose the corresponding tensioning clamps according to the type and specification of the wires, and install them according to the correct installation method to ensure the safe operation of the wires.
Packing: Generally, we use wooden cases for packing and transportation. If you have any special requirements, please let us know.
Delivery: Usually, it will take about 20-25 days for the order of 10000 sets for production.
Payment terms: By T/T.